Choose Site Prep and Grading Cost for a New Substation. Select from below 138kV Substation - $1,500,000 230kV Substation - $1,800,000 345kV Substation - $2,200,000 500kV Substation - $2,600,000. Assumes the land is flat and barren (with no vegetation).Get price

Gas-Insulated Substations - GIS

Nov 10, 2010 · In other countries with space easily available, the higher cost of GIS relative to AIS has limited use to special cases. For example, in the U.S., only about 2% of new substations are GIS. International experience with GIS is described in a series of CIGRE papers (CIGRE, 1992; 1994; 1982).Get price

CAPITAL COSTS FOR TRANSMISSION AND SUBSTATIONS

The costs included in this report are believed to reasonably represent the cost to develop transmission and substation facilitiesin the WECC region . It is imperative to note, however, that transmission lines and substations are allunique, and the cost of a specific line or substation mayGet price

Gas insulated substation (GIS) versus Air insulated

Oct 28, 2020 · 3. Operation cost. The maintenance cost of GIS and AIS shall be equivalent. The cost for training in GIS is higher than in AIS. 4. Outage cost. Since the failure rate of GIS is lower, the outage cost of AIS shall be greater. 5. Disposal cost. The cost of decommissioning and disposal after use should be capitalized.Get price

Economics Between Conventional and Gas Insulated Substation

GIS Substation also offers unique advantages over air-insulated applications. GIS substations use insulating gas gas that reduces the distance needed between active and non-active switchgear parts, resulting in smaller overall space requirements. Southern California Public Power Authority Awards ABB Order for GIS Substation Project. (2004, February) Figure 1.Get price

SCE 2017 Per Unit Cost Guide

2.0 x 1.35 =2.7. Total Delta (summation of applied factor) Estimated cost per mile including applied factors ($ million/ mile) AG, PB, AFUDC, or ITCC. Typical configuration for 500 kV, includes "pair" of N/S or E/W buses. Used in substation expansion.Get price

5 Differences Between Air-Insulated Substations and Gas

ConstructionInstallationOperationMaintenanceTotal Cost of OwnershipGIS high voltage substationengineering uses the gas sulfur hexafluoride for insulation, whereas AIS uses air insulation in a metal-clad system. Sulfur hexafluoride is five times heavier than air and offers excellent extinction behavior. Another significant construction-based difference between the two switchyards is that a metal-clad AIS uses three-position draw-out circuit breakers (on, off and test). GIS systems use fixed, mounted circuit breakers. The sealed mounted breakers are a ‘sealed-for-life’ technology, whereas the AIS breaker can be removed for maintenance and troubleshooting.Get price

Jordanfirst 400 kV GIS substation completed - Modern Power

The Rolls-Royce contract, worth around $54 million, covered turnkey supply of the 400 kV Aqaba substation, the termination station at the Aqaba end of the submarine cable, three sets of air insulated equipment to interface between the 400 kV gas insulated switchgear and the overhead lines for the Egypt and Amman South feeder circuits, the extension to the existing 132 kV GIS and the protection equipment for Naqab, which forms the link with the Egyptian grid.Get price

Transmission Cost Estimation Guide - misoenergy.org

Feb 12, 2019 · costs were escalated 2.5% from values shown in MISO’s cost estimation guide for MTEP 2018. Disclaimer: This document is prepared for informational purposes only to support MISO planning staff in developing cost estimates and deriving benefit-to-cost ratios for solutions proposed for inclusion in the MISOGet price

8- Gas Insulated VS Conventional

GAS INSULATED SUBSTATION (GIS) Vs CONVENTIONAL OUTDOOR SUBSTATION (AIS) By ENGR. RIAZ AHSAN BAIG Year of Publication 2004 0 ABSTRACT The author in his paper has made comparison of Gas Insulated Substation (GIS) with Conventional Air Insulated Substation (AIS). According to the author GIS are much more reliable, compact and maintenance free.Get price

Costing- HVPNL

Description Unit Qty. Unit cost (In Cr.) Total cost (In Cr.) Ref. 1 Establishment Cost of each 220 KV Sub-Station No. 2 10 20 Sr.-18, Pg-114 (PGCIL DPR) 2 Land Cost of each 220 KV Sub-Station No. 2 10 20 Tentative cost as per prevailing market rates. 3 220/66 kV, 160 MVA transformer No. 6 7 42 Sr.-8,9,10 Pg-113 (PGCIL DPR) 4 220 /66 kV, 160 MVAGet price

Gas Insulated Substation at Best Price in India

Call +91-8048615300. Contact Supplier Request a quote. Hybrid Gis Substation Design And Drawings ₹ 10 Lakh/ Piece. Get Quote. 220/132kv Gas Insulated Substations ₹ 20 Lakh/ No. Get Quote. Sub Station Insulator. ₹ 1/ Piece Get Latest Price. We provide SubStation Insulator in high strength and high quality.Get price

GIS substations - Hitachi ABB Power Grids

The robust and low maintenance GIS based design minimizes the substation’s footprint by as much as 70 percent, enabling it to be installed indoors, in busy urban areas and in harsh environments. Our in-depth knowledge of the power value chain, as well as grid codes and utility practices in use around the world, enable us to provide turnkeyGet price

Gas Insulated Substations VS Air Insulated Substations | BLUE

Feb 12, 2020 · GIS Substation Simply put, in the GIS system, all the live components are enclosed in a grounded metal enclosure, then the whole system housed in a chamber full of gas. Gas insulated substations (GIS) primarily use sulphur hexafluoride gas as the primary insulator.Get price

Upgrading Substations: Cost Comparison | NOJA Power

13.2kV Substation equipment. 1 Per Unit(reference value) 0.82 Per Unit. 33kV Substation equipment. 1 Per Unit(reference value) 0.61 Per Unit. Cost Breakdown: Civil. 1 Per Unit(reference value) 0.34 Per Unit. Cost Breakdown: Electromechanical. 1 Per Unit(reference value) 0.79 Per UnitGet price

gaz sf6 (GIS) gas insulated substation Manufacturer in China

The disadvantage of GIS gas insulated substation: 1. The cost will be higher than the normal substations. 2. When there is a fault, it will take much more time to find the causing reason and repair the GIS substation. 3.Get price

Chapter 6 Substation and Transmission Line Facilities

b) The overall area dimensions of the substation will be considered as 320m x 270m including temporally storage area, site offices etc. c) The 400kV GIS outgoing feeders are connected to 400kV Over Head Transmission Lines. d) 400kV GIS and 250MVA/3 transformers are connected by overhead conductors.Get price

Introduction to Gas Insulated Substations ~ EUCI

Jun 29, 2017 · This course will attempt to provide an in-depth understanding of Gas Insulated Substations (GIS), including design, construction, operations, and maintenance. Attendees will gain a perspective from both an original equipment manufacturer (OEM) and utility on the lifecycle journey to a GIS installation including costs and long-term ROI.Get price

Gas-insulated switchgear | Portfolio | Siemens Energy Global

The 8DQ1-type HIS is a compact switchgear solution for a rated voltage of up to 550 kV. It is mainly used for cost-efficient renewals or expansions of air-insulated outdoor and indoor substations, particularly if the operator wants to make modifications while the switchgear is in service. Main features: For rated voltage of up to 550 kVGet price

PGE Phases Out insulating gas in HV Substation GIS | TD World

Jan 27, 2020 · The utility’s first purchase of a dry-air/vacuum GIS was for its Evolution substation at the Livermore, California, U.S., training center. Most recently, the utility purchased a second dry-air/vacuum GIS for a 115-kV, 50-kA, 3000-A multi-bay GIS at its new Hunters Point substation.Get price

Laois-Kilkenny Reinforcement Project

3.2 GIS Substation Size 7 4 Maintenance Operational Flexibility 8 4.1 AIS Maintenance Requirements 8 4.2 GIS Maintenance Requirements 8 4.3 AIS v GIS – Operational Flexibility 8 5 Substation Capital Costs 9 5.1 Substation Land Acquisition Costs 9 5.2 AIS HV Equipment Costs 10 5.3 GIS HV Equipment Costs 10Get price

E-045 Gas Insulated Substation Definitions and Basics

production costs of the metallic cases as pressure vessels of the GIS apparatus are huge. Due to this, some GIS arrangements are grouped to address several voltage ratings. One equipment technical standard addressing rated voltages of 110 kV, 123 kV, 138 kV, and 145 kV, is described by the same class of GIS with the same case.Get price

Gas-insulated switchgear (GIS) - Hitachi ABB Power Grids

As a result, Hitachi ABB Power Grids'GIS offers outstanding reliability, operational safety and environmental compatibility. It provides a complete range of products for all ratings and applications from 72.5 kV to 1200 kV matching current and future requirements for modern switchgear.Get price

GE Grid Solutions

GE provides Gas Insulated Switchgear (GIS) Substations ranging from 69kV to 500kV for utilities and industrial customers with a full complement of primary and secondary equipment, services and solutions to build and retrofit electrical infrastructure. GEcompact and modular design minimizes the installation footprint.Get price

Medium Voltage blue GIS | Systems | Siemens Global

8DJH 12 – blue GIS for sustainable substation BKK Nett AS in Bergen, one of the most innovative Utilities in Norway, had a clear goal for a new MV switchgear for distribution substation: A compact ring main unit that would operate more sustainably, reliably and economically and could work at very low operation temperatures.Get price

GIS 400kv substation - SlideShare

May 17, 2018 · Demerits of GIS High cost compared to conventional substation(AIS). Excessive damage in case of internal fault. Diagnosis of internal fault and rectifying takes very long time (high outage time). Reduction in the pressure of the Sulfr hexafluoride gas in any module results in flash over and faults. Sulfr hexafluoride causes ozone depletion and global warming.Get price

(PDF) Design and Costs Estimation of Electrical Substations

6.2 Costs Engineering Module In this module the list of all elements generated in the design module are linked auto- matically to estimate the costs for building that substation. The associated costs for each building block are stored in a catalogue of concepts which describes the techni- cal specifications and costs based on their unit prices.Get price

Jornada técnica en subestaciones

13:20 Life Cycle Cost 13:40 Compare AIS and GIS C37.122.2 Guide for Application of Gas-Insulated Substations (GIS) 1 kV up to 52 kV Interrupter unit PostGet price