Web GIS for Iraqi Electrical Grid System

widely consists of Iraq, but near the two major rivers (Tigris and Euphrates) are productive alluvium plains, as the rivers carry around 60,000,000 m3 of grainy annually to the delta. The north of Iraq mostly consists of mountains; the highest point being at 3,611 m (11,847 ft.) point, nameless on the map, but known locally as Cheekah-Dar.Get price

Rebuilding IraqSpatial Infrastructure With GIS

Rebuilding IraqSpatial Infrastructure With GIS: As those involved in urban planning and development are well aware, the reconstruction of a nationspatial infrastructure is virtually as important as the reconstruction of its physical infrastructure.Get price

Construction of 33/11Kv GIS Substations (2 x 31.5 MVA

Switchgear with /33 11kv SS equipment intended to be used in the system of the MOE ,IRAQ. The contract shall include all works and materials needed in each substation in accordance with the contract and shall include but not limited to the following: (a) Option 1: 33kv switchgear contain: 1- two of 33kv incomer panel.Get price

Solar resource maps and GIS data for 200+ countries | Solargis

The maps and data for Iraq have been released in parallel with Global Solar Atlas, which is published by the World Bank Group, funded by ESMAP, and prepared by Solargis. All maps on this page are licensed by The World Bank under the Creative Commons Attribution license ( CC BY 4.0 ) with the mandatory and binding addition presented in GlobalGet price

GAS INSULATED SWITCHGEAR

i) Dew point meter ii) Leakage detector iii) Precision pressure gauge h) The required overall parameters of GIS are as follows: SL NO TECHNICAL PARAMETERS 400 KV SYSTEM 220 KV SYSTEM 132 KV SYSTEM 1. Rated Voltage 420 KV (rms) 245 KV (rms) 145 KV (rms) 2. Rated Frequency 50 Hz 50 Hz 50 Hz 3. GroundingGet price

Gas-Insulated Substations - GIS

Nov 10, 2010 · A gas-insulated substation (GIS) uses a superior dielectric gas, insulating gas, at moderate pressure for phase-tophase and phase-to-ground insulation. The high voltage conductors, circuit breaker interrupters, switches, current transformers, and voltage transformers are in sf 6 gas inside grounded metal enclosures. The atmospheric air insulation used in a conventional, air-insulated substation (AIS) requires meters of air insulation to do what insulating gas can do in centimeters.Get price

Gas-Insulated Substations : GE Grid Solutions

Gas-Insulated Solutions. GE designs, manufactures, installs and services a full range of state-of-the-art Gas-Insulated Substations (GIS) for utilities and industries worldwide. The portfolio includes GIS solutions from 60 to 800 kV, along with hybrid, mobile and digital GIS solutions, Gas-Insulated lines and other secondary products to maximize switchgear and network operation, including spring-operated mechanisms for AIS, GIS and generator circuit breakers.Get price

Construction and Service Life of GIS Substation - An

May 25, 2019 · GIS is assembled of standard equipment modules (circuit breaker, current transformers, voltage transformers, disconnect and ground switches, interconnecting bus, surge arresters, and connections to the rest of the electric power system) to match the electrical one-line diagram of the substation.Get price

Gas insulated substation (GIS) versus Air insulated

Oct 28, 2020 · Gas insulated substation (GIS) design. The metal-enclosed gas insulated switchgear inherently follows the criteria for new substation design and offers a higher reliability and flexibility than other solutions. Due to the gas enclosed design, GIS is the most suitable solution for indoor and underground substations.Get price

GIS Substation Design and Execution HV and EHV GIS

2014/04 - Houston - CED – GIS - 3 GIS introduction 1/7 Sulfr hexafluoride properties 1/3 zA GIS is the implementation, within a complete HV substation, of the remarkable sulphur hexafluoride (Sulfr hexafluoride) properties in terms of voltage withstand and current interruption zSulfr hexafluoride main data zNeutral gas: insulators and live parts are perfectly protectedGet price

GIS substations - Hitachi ABB Power Grids

Hitachi ABB Power Grids substations with gas-insulated switchgear (GIS) are unmatched when it comes to compactness, reliability, efficiency and safety, ensuring maximum power availability for utility, commercial and industrial customers. The robust and low maintenance GIS based design minimizes the substation’s footprint by as much as 70 percent, enabling it to be installed indoors, in busy urban areas and in harsh environments.Get price

ABB to Install Substation in Iraq | TD World

Aug 11, 2017 · ABB has won an order to supply and install a substation at the 3,000 MW Rumaila power plant, located in the Basra region of southern Iraq. The completed power plant will be operated by Shamara Holding Group (SHG), one of Iraq’s largest private industrial conglomerates and an independent power producer.Get price

Iraq Orders Substations to Strengthen Power Grid | TD World

Jun 22, 2018 · Jun 22, 2018. ABB has won orders from the Ministry of Electricity in Iraq to deliver five fixed and 15 mobile 132 kV substations that will help strengthen the power grid and provide electricity in central Iraq. The government of Iraq is rebuilding the country and investing in its grid as part of its ambitious plan to develop its power infrastructure to meet electricity needs.Get price

Gas-Insulated-Substations Sulfr hexafluoride gas handling

Sep 26, 2011 · Siemens GIS, Cable bay with double busbar system including 2 BB DS, 1 line DS, 1 CB, 3 ES dew-point temperature, High Voltage Substations ContinuousGet price

National Grid Begins Series of GIS Substation Replacements

Substation (GIS) at the Brayton Point generating station in Somerset, Mass. with a new, state-of-the-art indoor facility. The GIS, originally built in the early 1970s to support the New England bulk transmission grid, is approaching the end of its useful life. It also has been a focus ofGet price

PSP | ElSEWEDY

Project Name: Diwaneya 400 kV GIS Substation; Project Description: EPC (Engineering, procurement and Construction) of AL-DIWANIYA 400 kV GIS S/S; Owner: The Ministry of Electricity/General Directorate for Gas Power Plants Projects of the Republic of Iraq; Project Location: Diwaneya , Iraq; Main Contractor: JV of the Arab Contractors ELSEWEDY POWERGet price

5 Differences Between Air-Insulated Substations and Gas

ConstructionInstallationOperationMaintenanceTotal Cost of OwnershipGIS high voltage substationengineering uses the gas sulfur hexafluoride for insulation, whereas AIS uses air insulation in a metal-clad system. Sulfur hexafluoride is five times heavier than air and offers excellent extinction behavior. Another significant construction-based difference between the two switchyards is that a metal-clad AIS uses three-position draw-out circuit breakers (on, off and test). GIS systems use fixed, mounted circuit breakers. The sealed mounted breakers are a ‘sealed-for-life’ technology, whereas the AIS breaker can be removed for maintenance and troubleshooting.Get price

Iraqi Ministry of Electricity and GE Power celebrate

Jan 23, 2019 · Baghdad, Iraq; January 23, 2019: Underlining their joint commitment to support the development of Iraq’s power infrastructure, the Iraqi Ministry of Electricity (MoE) and GE Power’s Grid Solutions business (NYSE: GE) celebrated the energization of the Baghdad West North substation. Located about 35 kilometers away from the city, the substation can help connect up to 1,000 megawatts (MW) to the national grid, decreasing bottlenecks and increasing the hours of available power.Get price

Gas Insulated Substation (GIS) Electrical Power System | Udemy

Gas Insulated Substations. A gas insulated substation (GIS) is a high voltage substation in which the major structures are contained in a sealed environment with sulfur hexafluoride gas as the insulating medium. GIS technology originated in Japan, where there was a substantial need to develop technology to make substations as compact as possible.Get price

Reference Ardnacrusha Gis Substation in Ireland

Reference Ardnacrusha Gis Substation in Ireland 110 kV compact GIS enabling clean energy supply Located at the River Shannon that runs 360 km in length, Ardnacrusha is Ireland’s first and largest hydroelectric power plant owned and operated by the Electricity Supply Board (ESB) , Ireland’s largest utility.Get price

sf6 gas insulated switchgear purification device price

hgis Gas-Insulated-Substations purification device for sale. hgis Gas-Insulated-Substations purification device for sale. Oil Sands / Heavy Oil Upgrading GHG Methodology hexafluoride (sf 6) is a gas that is used in electrical equipment for the power transmission and distribution industry, as an insulating and arc interrupting gas.94%. Get PriceGet price

Abdul Chowdhury - Commissioning Engineer - EPS - LinkedIn

· Iver 275kV AIS substation – Responsible for assisting the commissioning engineers with activities such as function tests, SCADA, and RAMS. · Killingholme 400kV GIS substation – Responsible for refurbishment of GIS switchgear and performed dew point test to analyse condition of Sulfr hexafluoride gas.Get price

GIS | High-Voltage Gas Insulated Switchgear Substations

A gas insulated substation (GIS) is a high voltage substation in which the major structures are contained in a sealed environment with sulfur hexafluoride gas as the insulating medium. GIS technology originated in Japan, where there was a substantial need to develop technology to make substations as compact as possible.Get price

Gogoi inaugurates first gas-insulated substation - Facility

Feb 05, 2014 · Guwahati, Feb. 4: The Northeast today got its first gas-insulated switchgear (GIS) substation in the utility sector. The 220/33-kilo volt gas-insulated substation, built at a cost of Rs 49.56 crore and to be operated by the Assam Electricity Grid Corporation, will cater to newly developed areas of the city such as Dispur, Beltola, Basistha, Narengi, Khanapara and Panjabari, among others.Get price

Mahmoud Al-Salamat - Managing Director - ARC Energy W.L.L

- Testing engineer in power substation 400/132/33KV GIS and outdoor substation. - Good knowledge in Protection systems and… Testing Engineer responsible for installing and commissioning of high Extra high voltage power substations (400KV 132 KV) NEPCO (National Electrical Power Company) 2005-up to now (1 project 400KV, 5 project 132KV 6Get price

Ahmed Zaki - Senior Field Service Engineer - ABB | LinkedIn

 Al-Mosul ABB GIS (132-400) kV substation (SS) full installations (off loading, leveling, mechanical insulation, jointing with old equipment, GIS cable sealing end installation, sf 6 gas treatment,...Get price

Ali Mezaoui - Electrical Commissioning Engineer - Daewoo

- sf6 gas Gas DEW point measurement, density and leak tests - Provide support… Project: RAS DJINET 1131.1 MW COMBINED CYCLE POWER PLANT • Electrical commissioning engineer and client coordinator of 400KV Gas Insulated Switchgear (GIS) substation of 8 bays in RAS-DJINET project . My duties varied from:Get price

Alstom TD India to supply Power Grids first Make in India

May 12, 2015 · Alstom TD India has been awarded a contract worth approximately 34 million (INR 2266 million) by Power Grid Corporation of India Limited (Power Grid) to supply two Gas-Insulated Substations (GIS). The two substations will be located at Betul in Madhya Pradesh and Navsari in Gujarat. Both substations will be completely manufactured in IndiaGet price