ABB wins $40 million order for eco-efficient substation in

Nov 05, 2018 · ABB has won an order of around $40 million from German transmission grid operator TransnetBW to upgrade a high-voltage substation in Obermooweiler, in the German state of Baden-Wuerttemberg. As an integral part of the upgrade, ABB will install the world’s first 380-kilovolt (kV) gas-insulated switchgear (GIS) which uses an environmentally friendly alternative gas mixture to the industry standard SF 6 .Get price

ABB wins million order for eco-efficient substation in Germany

ABB has won an order of around $40 million from German transmission grid operator TransnetBW to upgrade a high-voltage substation in Obermooweiler, in the German state of Baden-Wuerttemberg. As an integral part of the upgrade, ABB will install the world’s first 380-kilovolt (kV) gas-insulated switchgear (GIS) which uses an environmentally friendly alternative gas mixture to the industry standard sf 6.Get price

380 kV GIS substation, Bühl, Germany - Linxon

Apr 26, 2021 · Linxon will supply a 380-kilovolt (kV) Gas Insulated Switchgear (GIS) substation for the German transmission system operator TransnetBW in the town of Bühl, southwestern Germany. Upgrading and strengthening the ‘Badische Rheinschiene’ power link in the Rhine valley will give TransnetBW a stable grid to transmit electricity generated by northern windfarms to consumers in the south, while nuclear and coal power plants are being put out of service.Get price

GIS for digital substations - Hitachi ABB Power Grids

Hitachi ABB Power Grids' GIS can be equipped with control, protection and communication feature for smooth integration into substation automation systems using IEC 61850. For connection to the IEC 61850-9-2 process bus, non-conventional instrument transformers (NCITs) for GIS with merging units are used for sampled values for protection and metering.Get price

GIS substations - Hitachi ABB Power Grids

Hitachi ABB Power Gridsdelivered the world’s first GIS substation in 1965, pioneering GIS technology; Comprehensive experience in indoor, outdoor and underground GIS substation design and construction; Proven, state-of-the-art equipment up to 1,100 kV; Complete in-house system integration capabilitiesGet price

GIS for Toshka 2 substation Prepared by ABB Company

May 18, 2020 · ABB company managed to provide 6 bays of 500 kV GIS for the Toshka2 substation in Egypt country. El Sewedy Electric TD contracted ABB to deliver high voltage gas insulated switchgear and shunt reactors to ensure reliable power supply as part of the strategic expansion of the Toshka 2 substation. This expansion, in the second phase of the 300-megawatt (MW) electric interconnection project between Egypt and Sudan, is an important step to transform Egypt into a regional hub for electricityGet price

Substations Transmission and distribution substations - ABB

ABB has a track record of more than 100 years in building AIS substations. GIS substations: offering compactness, reliability, safety and low maintenance. ABB pioneered GIS and commissioned the first gas-insulated substation in 1967. Hybrid substations: combining the advantages of AIS and GIS technologies. ABB supplies hybrid solutions since the lateGet price

ABB to upgrade landmark substation in Helsinki

Jun 05, 2018 · As part of the project, ABB replaced an outdoor air-insulated switchgear (AIS) installation with its innovative compact gas insulated switchgear (GIS) technology, freeing up 70 percent of the space occupied by the old facility, and locating the new substation within a stunning edifice that has become a renowned city landmark.Get price

ABB Locations Map

ABB Limited. Belgard Road Tallaght County Dublin +353 1 405 7300 +353 1 405 7327; ABB Limited. Mombasa Road Clifton Park, Mezzanine Floor 00623 Nairobi Kenya +254 20 357 9817 / +254 20 357 9818 / +254 269 6458/ +254 269 6459 +254 20 820 169 / +254 20 820 172; Asea Brown Boveri Industrial, Technical Commercial Company of Imports – Exports SGet price

Gas insulated substation (GIS) versus Air insulated

Oct 28, 2020 · Gas insulated substation (GIS) design. The metal-enclosed gas insulated switchgear inherently follows the criteria for new substation design and offers a higher reliability and flexibility than other solutions. Due to the gas enclosed design, GIS is the most suitable solution for indoor and underground substations.Get price

Project report 110 kV gas-insulated ring busbar - ABB

vative technologies in the fi eld of substations and substation automation all rank among our key corporate competences. ABB’s portfolio for GIS high-voltage switchgears from its High-Voltage Products Division includes several modularized series for rated voltages ranging from 52 kV to 1100 kV. More than 14,000Get price

Eco-efficient gas insulated switchgear | Medium Voltage - ABB

SÜC Coburg, Germany. Web story. ABB supplied MV GIS and REX640 to the Bavarian power utility SÜC Coburg in February of this year. SÜC Coburg, the public utility of Coburg, built a new substation in Schweighof using 24 panels of ABB’s state-of-the-art technology, ZX2 AirPlus Digital.Get price

ABB wins $40 million order for eco-efficient substation in

May 11, 2018 · Electrical substation upgrade with innovative gas-insulated switchgear helps TransnetBW to reduce environmental impact. ABB has won an order of around $40 million from German transmission grid operator TransnetBW to upgrade a high-voltage substation in Obermooweiler, in the German state of Baden-Wuerttemberg. As an integral part of the upgrade, ABB will install the world’s first 380-kilovolt (kV) gas-insulated switchgear (GIS) which uses an environmentally friendly alternative gas mixtureGet price

ABB Wins $40 Million Order For Eco-efficient Substation In

Nov 16, 2018 · ABB has won an order of around $40 million from German transmission grid operator TransnetBW to upgrade a high-voltage substation in Obermooweiler, in the German state of Baden-Wuerttemberg. As an integral part of the upgrade, ABB will install the world’s first 380-kilovolt (kV) gas-insulated switchgear (GIS) which uses an environmentally friendly alternative gas mixture to the industryGet price

Sf6 purity analyzers in switchgears - Switchgear Content

May 20, 2020 · A typical gas purity meter is shown in Figure. Sulfr hexafluoride purity measurement is displayed directly in % Volume Sulfr hexafluoride. Today, most of gas analyzers have the ability to measure purity and humidity and Dew/Frost Point, and other characters. Sulfr hexafluoride purity is typically measured using conductivity or speed of sound measurement techniques.Get price

GIS substations

Hitachi ABB Power Gridsdelivered the world’s first GIS substation in 1965, pioneering GIS technology; Comprehensive experience in indoor, outdoor and underground GIS substation design and construction; Proven, state-of-the-art equipment up to 1,100 kV; Complete in-house system integration capabilitiesGet price

ABB wins $40 million order for eco-efficient substation in

The new 380-kV Obermooweiler GIS substation, is a further milestone, positioning ABB at the forefront of eco-efficient innovations. It supports Germany’s targeted reduction of 40 percent in greenhouse gas emissions by 2020 and up to 95 percent by 2050.Get price

ABB secures contract to upgrade high-voltage substation in

Nov 06, 2018 · The new 380kV Obermooweiler GIS substation is expected to support Germany in meeting its greenhouse gas emissions reduction target by 40% by 2020 and up to 95% by 2050. TransnetBW managing director Dr Werner Götz said: “With this project, we are pleased to pave the way for a technical innovation that can make an important contribution toGet price

Linxon wins German substation order | Power Transformer News

Feb 25, 2021 · Posted by Patrick Haddad. Linxon has been selected to supply a 380-kilovolt (kV) Gas Insulated Switchgear (GIS) substation for the German transmission system operator TransnetBW in the town of Bühl, southwestern Germany. For this project, Linxon will design, supply, install and commission a 380 kV GIS substation to replace an existing 220 kV substation, which it will dismantle as part of the contract once the new GIS equipment has been put into operation.Get price

Integrated GIS for 145 - 420 kV

Integrated gas-insulated switchgear is a predesigned, standardized and fully integrated configuration based on Hitachi ABB Power Grids' well proven GIS technology. The integrated GIS provide substantial reduction of installation time compared to conventional substations.Get price

New Sulfr hexafluoride Leakage Test Unit for GIS Components | TD World

Sep 06, 2011 · Test and Measurement; New gaz sf6 Leakage Test Unit for GIS Components. DILO Armaturen und Anlagen GmbH in Babenhausen (Germany), has developed a new Sulfr hexafluoride leakage test unit allowing detection of even smallest leakages within a short period of time.Get price

Substations Flexible, reliable EPC solutions built from

ABB provided the engineering, procurement, construction and commissioning of the three substations ranging from 115 kV to 38 kV, to finally 13.2 KV with a combined total of 122 bays. The project has demonstrated superior reliability, enhanced system stability, and lowered operating and maintenance costs.Get price

ABB powers Africa’s largest gas-insulated switchgear installation

Feb 07, 2019 · To address the needs of growing electricity demand, Sebenza substation will supply help in the delivery of an additional 30 percent electricity into the national grid. The Sebenza substation features 38 bays of 132 kilovolt (kV) gas-insulated switchgear (GIS) from ABB, making it the largest installation of GIS at this voltage level to be commissioned in Africa.Get price

PSEG Orders GIS for Substations | TD World

Nov 13, 2015 · PSEG Orders GIS for Substations. Gas-insulated switchgear (GIS) order worth around $40 million to protect network from severe weather and enhance power reliability. Nov 13, 2015. ABB has won an order worth around $40 million in the United States, from Public Service Electric Gas to supply gas-insulated switchgear to two substations and help strengthen grid reliability.Get price

Gas-Insulated Substations - GIS

Nov 10, 2010 · Superior Dielectric Gas. A gas-insulated substation (GIS) uses a superior dielectric gas, Sulfr hexafluoride, at moderate pressure for phase-tophase and phase-to-ground insulation.The high voltage conductors, circuit breaker interrupters, switches, current transformers, and voltage transformers are in insulating gas gas inside grounded metal enclosures.Get price

Operation and Maintenance Customer Training Gas - ABB

The on-site training takes place at the substation. — Ras Laffan substation ABB is a leader in high-voltage GIS technology with a global installed base of more than 30,000 bays. The training covers three main areas. The following program is used for reference. The program can be adjusted according to special customer needs. Main components ofGet price

Gas-insulated switchgear | Portfolio | Siemens Energy Global

Siemens Energy LPITs are innovative voltage and current transformers providing a safe, reliable and standardized solution for measurement and protection applications in GIS. Without saturation nor ferro-resonance phenomena, our LPIT provides a digital signal output signal acc. to IEC 61850-9-2 or can be plugged directly into a Siemens SIPROTECGet price

ABB High Voltage Service Gas Management Solutions

ABB offers a complete SF 6 gas management solution, in an efficient and environmentally friendly manner, from installation to decommissioning. With the largest installed base of high voltage circuit breakers in North America, ABB is widely known for its switchgear expertise. ABB High Voltage Service (US) started offering SF 6 gasGet price

Partial Discharge Analysis in HVDC GIS (Gas Insulated

Gas Insulated Substations (GIS) respond to the expansion of the grid as well as the scarcity of available locations to build substations. In fact, GIS are multi-equipment systems in which the insulating medium is mainly sf 6 whose insulating properties permits to drastically reduce the dimensions of the substation in comparison to a traditionalGet price